6 – proper disinfectant level
.17(1)(a)(b) – proper disinfectant level
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed chlorine disinfection level of pool at time of inspection to be 0.5 ppm or less. Required disinfection level for pool is to be 1.0 – 10.0 ppm. CPO and RP is to adjust chlorine disinfection level to within ideal range of 3.0 to 5.0 ppm.
7 – ph between 7.2 and 7.8
511-3-5-.17(2) – (2) chemical values: ph
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed pH level of pool at time of inspection to be less that 7.0. CPO and RP is to adjust pool pH to ideal range of 7.4 – 7.6 (min/max range 7.2 – 7.8).
10 – pump: approved, maintained and operating
511-3-5-.09(1) – (1) sizing. a pump and motor shall be provided for circulation of the pool and spa water. performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic h
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Swimming pool pump was malfunctioning at time of inspection (not priming or circulating). CPO and RP were contacting pool maintenance company to repair or replace pool pump.
30 – deck/rinse shower maintained
511-3-5-.18(17) – (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Deck rinse shower at pool has not been repaired as noted at time of last inspection. RP has stated owner has contacted maintenance professional to repair shower and it is scheduled to be repaired. Deck shower is to be repaired within the next 30 days.
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(9) – (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed daily water test results and daily self-inspections are not being conducted as required by rules. CPO and RP are to begin logging/record keeping of daily water testing and safety checks immediately.