Flint River RV Park Tourist Accommodation Report

Violations

12 – hoses for filling water tanks/cleaning dump station pads properly stored and handled; no other use

511-6-2-.07(4) – water supply-hose bibs

Points: 1

Corrected during inspection?: No

Repeat: Yes

Inspector Notes: Observed washout spigot at dump station not having a required backflow preventive device. Backflow prevention device is to be installed at spigot by 9/19/19, 8:00 AM.


16 – toilet/lavatory/bathing facility fixtures and rooms clean and maintained; properly lighted, clearly marked, proper signage, and all in good repair

511-6-2-.08(4) – toilet facilities-cleaning and maintenance

Points: 2

Corrected during inspection?: No

Repeat: No

Inspector Notes: Observed men’s and women’s restrooms and showers at bathhouse in not clean. Observed dirty floors, mold/mildew build up on shower floors and walls. Both restrooms are to be thoroughly deep cleaned to sight and touch by 9/19/19.


18 – toilet tissue and soap provided; soap individually wrapped or properly dispensed

511-6-2-.08(7) – soap available/dispensed

Points: 2

Corrected during inspection?: No

Repeat: Yes

Inspector Notes: Observed no soap provided in men’s and women’s restrooms as requried by Rules. Bar soap was provided in women’s restroom for common use. Dispenser’s in men’s restroom was broken and is to be replaced. Dispenser in women’s restroom was empty and it is to be refilled. Owner can provide pump soap dispensers or provide individually wrapped single use bar soap as an alternative to wall mounted dispenser. Soap is to be provided in both restrooms by 9/15/22.


20 – sewers and drains maintained, connections capped

Points: 1

Corrected during inspection?: No

Repeat: Yes

Inspector Notes: Observed missing or busted sewer caps at Lots 32, 61, 71, 72. Sewer caps are to be be replaced by 9/19/22.


31 – barrier adequate, gate locked, and installed properly; warning sign posted, procedures and log maintained

511-6-2-.16(2) – swimming pool barrier

Points: 2

Corrected during inspection?: No

Repeat: No

Inspector Notes: Observed swimming pool entry gate torn off hinges and self locking closure busted. Owner or PIC not available at time of inspection. Posted pool closure sign on gate. Straightened gate and wire tied it shut. See 9/14/22 swimming pool inspection report for further information. Phone conversation with owner concerning pool closure. Gate and self-locking closure to be repaired 9/15/22 and owner call for reinspection.


34 – grounds, walkways, porches and hallways maintained; drives provide unobstructed width and proper spacing; graded to drain; trailer spaces marked clearly, areas clean and maintained in good repair

511-6-2-.18(3) – areas in good repair/appropriate storage

Points: 3

Corrected during inspection?: No

Repeat: No

Inspector Notes: Observed suspect water leak at RV space 73. Large area of ponded water was noted around spigot connection. Investigate possible leak and repair as needed by 9/19/22.


Leave a Reply

Your email address will not be published. Required fields are marked *